Fit check
Typical 400W panel ≈ 65" × 39". Check your panel spec sheet.
3 ft is common under IRC fire-access rules; your jurisdiction may differ.
Frequently asked
Do panels have to face south?
South-facing is best in the Northern Hemisphere, but east/west roofs still produce well (roughly 80–85% of south). North-facing sections are usually skipped. Azimuth matters less than avoiding shade.
How much does a panel weigh?
A typical residential panel weighs 40–50 lbs, spread over its mounting points. Most modern roofs handle this fine, but older roofs may need a structural check — your installer confirms this.
How this estimate works
The estimator shrinks your roof section by the setback on all four sides, then tiles panels across the remaining rectangle twice — once in portrait (tall side up), once in landscape — and reports whichever orientation fits more panels. Panel dimensions default to a typical modern residential panel, about 65 by 39 inches at 400 watts, but panels vary by model, so measure against the spec sheet of the panel you are actually quoted. The result is a count for one clear rectangular section. Real roofs are chopped up by vents, chimneys, skylights, and dormers, and installers also leave working room around obstructions, so treat the number here as a ceiling for that section, not a promise. If two orientations tie, portrait is usually cheaper to rack on a wide roof because the rails run shorter spans.
Examples
Standard gable section, 30 × 20 ft. With 3-foot setbacks the usable area is 24 × 14 ft. Portrait panels (about 5.4 ft tall) stack two rows of twelve: 16 to 24 panels depending on exact panel width — the estimator's answer for typical 400W panels is 16, about 6.4 kW from this one section. That is a full system for many homes, from a single clean roof face.
Small section, 18 × 12 ft. Setbacks leave 12 × 6 ft. One row of portrait panels fits — roughly 6 panels, 2.4 kW. Sections this size are usually combined with a second face rather than used alone, and installers may skip a face this small if the racking cost per panel gets silly.
Long ranch section, 44 × 16 ft. Usable 38 × 10 ft fits two portrait rows of about 19, or roughly 28 to 38 panels across orientations — more than most homes need, which is the good problem: the constraint becomes your electrical panel and usage, not your roof.
Worked example: what 16 panels are worth
The standard gable section above fits 16 panels at 400 W each, a 6.4 kW array. Two numbers from our system sizer turn that count into money. At the sizer's installed cost of $3.36 per watt, the array runs about 6,400 × $3.36 = roughly $21,500 before any state incentives. For production, take 6.4 kW times 4.5 peak sun hours a day, a mid-range figure from the sun-hours table, times the 0.80 derate the sizer applies for wiring, inverter, and soiling losses: about 23 kWh a day, or roughly 8,400 kWh a year. At the payback calculator's default electricity rate of $0.18 per kWh, that is about $1,500 a year of avoided purchases if every kilowatt-hour offsets your bill. Your sun hours and rate will differ, sometimes a lot, which is why the sizer asks for your state and your actual bill. The layout count is the input everything else multiplies, so it is worth measuring your roof section carefully before running the money math. A two-panel error in the count is an $800 error in the cost estimate and a 900 kWh error in the production estimate, before any other assumption gets a say.
Common layout mistakes
- Measuring the roof from the ground. The footprint of a pitched roof is shorter than the sloped surface the panels actually sit on. Measure along the slope, or multiply the flat measurement by the pitch factor, or your rows will not fit.
- Treating a chopped-up section as one rectangle. A vent pipe or chimney does not just remove its own footprint; racking needs working clearance around it, and a row that hits an obstruction often ends early.
- Assuming portrait always wins. On tall, narrow sections, landscape fits more panels. That is why the estimator tries both orientations instead of asking you to guess.
- Counting panels your electrical panel cannot serve. A full roof is not a full system if the service panel and local rules cap the inverter size. The roof is rarely the only constraint.
- Ignoring shade math. A section that fits 16 panels but loses three hours to a neighbor's oak is worth less than a smaller, clear section. Fit is geometry; value is sunlight.